outerdiameter.com

ASTM D2241 ·size chart

PVC 2 outer diameter: 2.375 in / 60.325 mm

OD (inches)
2.375 in
OD (millimetres)
60.325 mm
DN
50
Wall range
0.154–0.218 in
Bore range
1.939–2.067 in

PVC pressure pipe (CTS-adjacent iron pipe sizes). Walls are minimums, so a derived bore is a maximum. For PVC 2, ASTM D2241 fixes the outside at 2.375 in / 60.325 mm; the 2 published wall series below are what change the bore.

ASTM D2241 PVC 2 — every published wall series. Mass is derived, not published: PVC, ρ = 1400 kg/m³, ρ·π/4·(OD²−ID²). Real pipe weighs more (ends, coating, tolerances).
Wall seriesWall (in)Wall (mm)ID (in)ID (mm)Bore is≈ kg/m
Sch 400.1543.9122.06752.502a maximum0.97
Sch 800.2185.5371.93949.251a maximum1.33

Same body, different material. steel 2 Sch 40 = STD, and PVC 2 Sch 40, and stainless 2 Sch 40S are the same 0.154 in wall on the same 2.375 in / 60.325 mm body; steel 2 Sch 80 = XS, and PVC 2 Sch 80, and stainless 2 Sch 80S are the same 0.218 in wall on the same 2.375 in / 60.325 mm body. A caliper cannot separate them — what the pipe is made of does.

The same nominal label in other standards

Same nominal label, different bodies — these are not interchangeable parts.
StandardOD (in)OD (mm)DNPublished wall series
ASME B36.10M · welded and seamless steel pipe2.37560.32550Sch 10 0.109 · Sch 40 0.154 · Sch 80 0.218 · Sch 160 0.344 · STD 0.154 · XS 0.218 · XXS 0.436
ASTM D2241 · PVC pressure pipe2.37560.32550Sch 40 0.154 · Sch 80 0.218
ASTM F876/F877 (CTS) · PEX tubing (CTS)2.12553.97550no wall published yet (1 awaiting a second source)
ASME B36.19M · stainless steel pipe2.37560.32550Sch 5S 0.065 · Sch 10S 0.109 · Sch 40S 0.154 · Sch 80S 0.218

PVC vs steel — 2 (ASME B36.10M) · PVC vs PEX — 2 (ASTM F876/F877 (CTS))

Report a wrong value

Measuring this size

Questions about PVC 2

What is the outer diameter of PVC 2 pipe?

2.375 in / 60.325 mm — but that is only true for ASTM D2241. The same nominal label in ASTM F876/F877 (CTS) (2.125 in / 53.975 mm) is a different pipe. Calipers measure this number; the name does not.

What is the inside diameter of PVC 2 Sch 40?

2.067 in / 52.502 mm — the outer diameter minus twice the wall (2.375 − 2 × 0.154). This standard publishes a MINIMUM wall, so the bore is a maximum: a thicker pipe has a smaller bore. Other wall series for this size are in the table above.

Is PVC 2 the same as DN 50?

DN 50 is the millimetre-family name for this size, so yes for the size — no for the number. DN is not the outer diameter and not the bore; PVC 2 measures 2.375 in / 60.325 mm outside. See the NPS ↔ DN table for the whole series.

Sources for these numbers

Each wall value in this page's tables was confirmed by two independent publications; the list above is those pairs combined, so a source appears once even when it supports several rows. The outer diameter is published per size, not per wall. Data version 48d86b977106.

No edition year is claimed. These values match ASTM D2241 as published by the sources above, but the specific printing was not verified, so the standard is named without a year.