outerdiameter.com

ASME B36.10M ·size chart

NPS 2 outer diameter: 2.375 in / 60.325 mm

OD (inches)
2.375 in
OD (millimetres)
60.325 mm
DN
50
Wall range
0.109–0.436 in
Bore range
1.503–2.157 in

Welded and seamless wrought steel pipe. OD is fixed per size; the wall (schedule) is what you choose. For NPS 2, ASME B36.10M fixes the outside at 2.375 in / 60.325 mm; the 7 published wall series below are what change the bore.

ASME B36.10M NPS 2 — every published wall series. Mass is derived, not published: carbon steel, ρ = 7850 kg/m³, ρ·π/4·(OD²−ID²). Real pipe weighs more (ends, coating, tolerances).
Wall seriesWall (in)Wall (mm)ID (in)ID (mm)Bore is≈ kg/m
Sch 100.1092.7692.15754.788exact3.93
Sch 400.1543.9122.06752.502exact5.44
Sch 800.2185.5371.93949.251exact7.48
Sch 1600.3448.7381.68742.850exact11.12
STD0.1543.9122.06752.502exact5.44
XS0.2185.5371.93949.251exact7.48
XXS0.43611.0741.50338.176exact13.45

Same body, different material. steel 2 Sch 40 = STD, and PVC 2 Sch 40, and stainless 2 Sch 40S are the same 0.154 in wall on the same 2.375 in / 60.325 mm body; steel 2 Sch 80 = XS, and PVC 2 Sch 80, and stainless 2 Sch 80S are the same 0.218 in wall on the same 2.375 in / 60.325 mm body. A caliper cannot separate them — what the pipe is made of does.

The same nominal label in other standards

Same nominal label, different bodies — these are not interchangeable parts.
StandardOD (in)OD (mm)DNPublished wall series
ASME B36.10M · welded and seamless steel pipe2.37560.32550Sch 10 0.109 · Sch 40 0.154 · Sch 80 0.218 · Sch 160 0.344 · STD 0.154 · XS 0.218 · XXS 0.436
ASTM D2241 · PVC pressure pipe2.37560.32550Sch 40 0.154 · Sch 80 0.218
ASTM F876/F877 (CTS) · PEX tubing (CTS)2.12553.97550no wall published yet (1 awaiting a second source)
ASME B36.19M · stainless steel pipe2.37560.32550Sch 5S 0.065 · Sch 10S 0.109 · Sch 40S 0.154 · Sch 80S 0.218

steel vs PVC — 2 (ASTM D2241) · steel vs PEX — 2 (ASTM F876/F877 (CTS)) · steel vs stainless — 2 (ASME B36.19M)

Report a wrong value

Measuring this size

Questions about NPS 2

What is the outer diameter of NPS 2 pipe?

2.375 in / 60.325 mm — but that is only true for ASME B36.10M. The same nominal label in ASTM F876/F877 (CTS) (2.125 in / 53.975 mm) is a different pipe. Calipers measure this number; the name does not.

What is the inside diameter of NPS 2 Sch 40?

2.067 in / 52.502 mm — the outer diameter minus twice the wall (2.375 − 2 × 0.154). This standard publishes nominal wall, so the bore is exact within manufacturing tolerance. Other wall series for this size are in the table above.

Is NPS 2 the same as DN 50?

DN 50 is the millimetre-family name for this size, so yes for the size — no for the number. DN is not the outer diameter and not the bore; NPS 2 measures 2.375 in / 60.325 mm outside. See the NPS ↔ DN table for the whole series.

Sources for these numbers

Each wall value in this page's tables was confirmed by two independent publications; the list above is those pairs combined, so a source appears once even when it supports several rows. The outer diameter is published per size, not per wall. Data version 48d86b977106.

No edition year is claimed. These values match ASME B36.10M as published by the sources above, but the specific printing was not verified, so the standard is named without a year.